Vetrano Espresso Machine Installation Manual

Browse online or download Installation Manual for Coffee makers Vetrano Espresso Machine. Vetrano Espresso Machine Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
Digital Thermometer & Adaptor for E-61 Groupheads
November 20, 2007
Introduction:
The purpose of this adaptor and digital thermometer is to facilitate the measurement of
brew water temperature about 1.25" away from the puck during a brew cycle. In
addition, and EQUALLY IMPORTANT, it measures the temperature of the grouphead
at the indicated location under idle conditions. It requires no drilling, tapping, soldering,
brazing, cutting, teflon tape, or epoxy but is ONLY capable of fitment to E61 group-
heads that are fully exposed. The difference between the temperature that you will be
measuring using this adaptor and measured temperature of the water hitting the puck is
approximately 3-5 degrees F but may vary with different machines and different brew
conditions and most certainly, varies over the course of a typical 23-27 second shot.
Indicated temperatures will be higher than those presented to the puck when using the
flush-n-wait technique whereas indicated temperatures will be lower than those
presented to the puck when using the flush-n-go technique.
There have been several successful adventures in measuring brew water temperature
in espresso machines. The best example would be the Scace Thermofilter available
from this espresso supply house: http://www.espressoparts.com/
It is a well-engineered device, designed to measure brew temperature during an
accurately simulated double-shot brewing process. Instructions for the use of this
device and a professional review of it can be found here:
http://www.home-barista.com/forums/viewtopic.php?t=453
Page view 0
1 2 3 4 5 6 ... 20 21

Summary of Contents

Page 1 - Introduction:

1Digital Thermometer & Adaptor for E-61 GroupheadsNovember 20, 2007Introduction:The purpose of this adaptor and digital thermometer is to facilita

Page 2 - Development:

10NOTENo part of the 7/16 hex should be touching any part of the grouphead. If this is NOT the case, stop all work and give me a call at 301-587-5033

Page 3

11Installing the Digital Thermometer:Now that the adaptor has demonstrated itself to be leak free, it is time to install the digital thermometer which

Page 4 - Kit Contents:

12Remove the existing M6 x 8 mm allen-head capscrew using a 5 mm long-handle allen wrench. The existing copper or teflon sealing washer will likely c

Page 5 - Enhanced Kits:

13Operation of the Espresso Machine with Digital Thermometer:An E-61 espresso machine having a heat exchanger (hx) can be operated in numerous ways.

Page 6

14b. Flush the machine until the thermometer reads 184 F +/- 1 degree. A higher pstat setting such as 1.15 to 1.20 bar would benefit from a flush to

Page 7

15machine as each machine is different although certainly the temperature RESPONSE TIMES of the Quickmill Anita, Andreja, and Vetrano would be very si

Page 8

16G13-A and is also an alkaline battery. The exact “Energizer” replacement model number is A76; the exact “Duracell” replacement is PX76A.Radio Shack

Page 9

17Spare Parts:Nylon ferrule set Swagelok P/N NY-200-SET6 mm copper washer Copper sealing washer, 6.2 x 9.9 mm7/16” Nut Swagelok P/N SS-202-1Plug Swag

Page 10

18For sure that depends on the beans you are using but I have found that a measured average temperature of 203 F at the passageway intersection (with

Page 11

19When tightening the adaptor with a used copper washer, simply “snug it up” as it would require too much torque to deform it as in an original instal

Page 12

2Background:This adaptor is identical to the original thermocouple adaptor except that the “bored-through” size of the fitting is 1/8” (0.125”) vice t

Page 13 - Temperature, Degrees F

2014. Do I need any special tools to install this device?The ONLY tools you need are a 5 mm allen head wrench to remove the existing screw in the gro

Page 14

21FAQ

Page 15

3they are simply a very light press fit and will pull out with ease and a slight alternating, twisting motion. Putting the probe in a vise makes the j

Page 16

4Kit Contents:a. Stainless steel adaptor (Swagelok P/N SS-200-1-0221BT or equal) fitted with replaceable nylon ferrules and a modified Taylor Model 3

Page 17 - (in a very random sequence)

5Enhanced Kits:The primary purpose of the adaptor is to allow the use of the modified digital thermometer to assist in making your espresso better and

Page 18

6Checking the Accuracy of the Thermometer:The 3516 digital thermometer included in this kit is not capable of being calibrated but it is easy to check

Page 19

7Another method of “checking” YOUR digital thermometer kit is to immerse the thermometer tip in a covered short thermos jug filled with a mixture of c

Page 20

8The “D” dimension can be measured with a bent paper clip as shown above or with a thin coat hangar to which you can slide a piece of wire insulation

Page 21

9Vibiemme machines have a “D” dimension of 0.415 and thus the probe protrusion is set at 1/4" (actual is 0.257”). Temporary Installation of Therm

Comments to this Manuals